Check compatibility yourself

Does your fireplace work with Foom? — 3 quick questions

  • 1
    Does it have a wall switch? Look for a standard rocker or toggle switch that turns the fireplace on and off. If yes, continue to step 2. If it only has a key switch or physical valve knob, Foom is not compatible.
  • 2
    Are the switch wires low-voltage? Behind the switch plate, the wires should carry no mains power. Measure across the two switch terminals (with the pilot lit but switch open) — a millivolt system will read 250–750 mV DC; an IPI system will read 0–3 V DC. Either is compatible. If you read 24 V AC or higher, Foom is not compatible.
  • 3
    Is the wall switch wired, not wireless? Some current-generation fireplaces (primarily Majestic Meridian, Echelon, Ruby, Jade; and Valor L1/L2/Portrait/Legend) use a wireless RF wall switch with no wired terminals. These are not compatible without hardware modification.
Ignition system types

What kind of fireplace do you have?

Gas fireplaces use one of a few ignition and control systems. Compatibility with Foom is determined almost entirely by the system type — not the brand.

✓ Millivolt / Standing Pilot

The most common type. A thermopile heated by the standing pilot generates 250–750 mV, which powers the gas valve directly. The wall switch is a simple dry-contact that completes the circuit. Fully compatible — Foom's relay acts as an electronic version of the wall switch.

✓ IPI with dry-contact switch

Intermittent Pilot Ignition systems using a Dexen IntelliFire board, SIT ProFlame 1 or 2, Napoleon Pilot on Demand, or Empire electronic IPI all expose a simple two-wire dry-contact wall switch terminal on the control board. Foom works for on/off control.

✗ IntelliFire Touch (wireless RF)

Used by current-generation Majestic (Meridian, Echelon, Ruby, Jade) and some Vermont Castings models. The wall switch communicates wirelessly — there are no wired low-voltage switch terminals. Incompatible with Foom without hardware modification.

✗ Valor GV60 (Maxitrol 6 V)

Valor's GV60 electronic ignition system puts 6 V DC on the wall switch circuit (rather than a passive dry contact). The wall switch kit (1265WSK) carries powered signal. Incompatible with Foom's relay.

⚠ Check first: IPI variant models

Many brands sell the same model in both millivolt and IPI configurations. Some older lines were millivolt; current versions may have switched to IntelliFire Touch. Always check your model number suffix and verify against this list.

Model compatibility list

Find your fireplace

Search by brand or model name, or filter by compatibility status. "IPI – on/off" means Foom controls the fireplace on and off; your existing wall switch continues to work normally through Foom.

Brand Model / Series System type Compatible Notes
Empire Tahoe DVP / DVC (MV models) Millivolt, standing pilot Yes Suffix MV or DVP confirms millivolt; standard thermopile circuit
Empire Tahoe DVP / DVC (IPC models) IPI (electronic) Yes – IPI on/off IPC (Intermittent Pilot Control) version; dry-contact wall switch terminal on board
Empire Loft DVL36 / DVL46 IPI (electronic, battery backup) Yes – IPI on/off Includes manual wall switch; IPI with dry-contact two-wire terminal
Empire Boulevard DVLL (direct vent) IPI (electronic) Yes – IPI on/off IPI system with standard wall switch terminal
Empire Carol Rose OP36 / OP42 (MV) Millivolt, standing pilot Yes Outdoor millivolt models; standard thermopile circuit
Empire Madison Millivolt, standing pilot Yes Traditional millivolt series
Fireplace Xtrordinair 4415 HO Deluxe (MV variant) Millivolt, standing pilot Yes ProBuilder and some 4415 available in millivolt version
Fireplace Xtrordinair 4415 HO Deluxe (GreenSmart 2) IPI (SIT ProFlame 2) Yes – IPI on/off GreenSmart 2 uses SIT ProFlame 2; X4 connector is dry contact
Fireplace Xtrordinair 564 TRV (MV variant) Millivolt, standing pilot Yes MV suffix confirms millivolt
Fireplace Xtrordinair 564 SS / 564 TRV (GreenSmart 2) IPI (SIT ProFlame 2) Yes – IPI on/off GreenSmart 2; dry-contact relay works
Fireplace Xtrordinair 616 (MV variant) Millivolt, standing pilot Yes MV models available
Fireplace Xtrordinair 616 (GreenSmart 2 variant) IPI (SIT ProFlame 2) Yes – IPI on/off GreenSmart 2 IPI; relay works
Fireplace Xtrordinair 4015 (legacy) Millivolt, standing pilot Yes Legacy models were millivolt; confirm if GreenSmart upgrade was applied
Heat & Glo 6000C / 6000G (non-IPI) Millivolt, standing pilot Yes Classic millivolt models; wall switch closes thermopile circuit directly
Heat & Glo 6000CBV-IPI / 6000GBV-IPI IPI (Dexen IntelliFire) Yes – IPI on/off Switch terminals carry <3 V from Dexen board; dry-contact relay works
Heat & Glo 6000XLS / 6000XLT Millivolt, standing pilot Yes Standing pilot millivolt; full wall switch compatibility
Heat & Glo SLIMLINE (non-IPI suffix) Millivolt, standing pilot Yes Model number without "-IPI" indicates millivolt variant
Heat & Glo SLIMLINE SL-550TR-IPI / SL-750TR-IPI / SL-950TV-IPI IPI (Dexen IntelliFire) Yes – IPI on/off Relay replaces simple on/off function at Dexen board switch terminals
Heat & Glo ST series (non-IPI) Millivolt, standing pilot Yes Non-IPI ST variants use millivolt
Heat & Glo ST-36TR-IPI / PIER-36TR-IPI IPI (Dexen IntelliFire) Yes – IPI on/off Simple relay works at Dexen board switch terminals
Heat & Glo COSMO series IPI (IntelliFire / IntelliFire Plus – varies by year) Check first Newer COSMO models use IntelliFire Plus; may require proprietary WSK-21 switch. Verify model year and check if board has accessible dry-contact terminals.
Heat & Glo MEZZO series IPI (IntelliFire Plus) Check first IntelliFire Plus models may not expose simple 2-wire terminals; consult installation manual for your specific model year
Heatilator ICON series (pre-2020, non-IPI) Millivolt, standing pilot Yes Older ICON DV models with standing pilot; standard thermopile circuit
Heatilator ICON I100 (current) IPI (IntelliFire) Yes – IPI on/off Relay works at Dexen board switch terminals
Heatilator EL / Eclipse (older) Millivolt, standing pilot Yes Older Eclipse models used millivolt standing pilot
Heatilator SC / ST series (non-IPI designation) Millivolt, standing pilot Yes Models without IPI designation in the model number use millivolt
Heatilator CRAVE series IPI (IntelliFire / IntelliFire Touch – varies by year) Check first Newer CRAVE uses IntelliFire Touch (wireless only — incompatible). Older CRAVE may have standard wired option. Check model year carefully.
Kozy Heat Chaska 25 IPI (electronic) Yes – IPI on/off Standard IPI with dry-contact wall switch terminal
Kozy Heat Chaska 29 IPI (electronic) or Millivolt (optional) Yes Both IPI and optional millivolt available; both compatible
Kozy Heat Chaska 34 IPI (electronic) Yes – IPI on/off Standard IPI; dry-contact relay works
Kozy Heat Chaska 335s Millivolt, standing pilot Yes Confirmed millivolt standard on this model
Kozy Heat Callaway 50 / Callaway 72 IPI (SIT ProFlame) Yes – IPI on/off SIT ProFlame-based; X4 connector is dry contact; relay works
Kozy Heat Slayton 36 / Slayton 42 IPI (SIT ProFlame) Yes – IPI on/off Same SIT ProFlame system as Callaway; relay works
Majestic Meridian 36 / 42 IPI (IntelliFire Touch – wireless RF) Not compatible IntelliFire Touch uses wireless RF; no wired 2-wire low-voltage switch terminals available
Majestic Echelon II 36 / 42 / 60 IPI (IntelliFire Touch – wireless RF) Not compatible Same IntelliFire Touch system; no wired switch option available
Majestic Ruby series IPI (IntelliFire Touch – wireless RF) Not compatible IntelliFire Touch throughout current Ruby line
Majestic Jade series IPI (IntelliFire Touch – wireless RF) Not compatible IntelliFire Touch throughout current Jade line
Majestic Quartz series (older) IPI (IntelliFire / original Dexen) Yes – IPI on/off Older Quartz used standard IntelliFire (not Touch); relay works at Dexen board terminals
Majestic Marquis series Varies by generation Check first Some older Marquis were millivolt (compatible); newer generations may be IntelliFire or IntelliFire Touch. Verify model year.
Mendota DXV-35 / DXV-42 / DXV-45 (manual control) Millivolt, standing pilot Yes Manual control DXV models use millivolt valve; standard dry-contact wall switch
Mendota DXV-35 / DXV-42 (DT3 / DT4 – ProFlame 2) IPI (SIT ProFlame 2) Yes – IPI on/off ProFlame 2 X4 connector is dry contact; relay works; wireless transmitter is optional
Mendota ML39 / ML39-PF2 IPI (SIT ProFlame 2) Yes – IPI on/off Confirmed ProFlame 2 system; dry-contact wall switch
Mendota FV series / FullView IPI (SIT ProFlame 2) Yes – IPI on/off ProFlame 2-based; relay works
Monessen Aria (millivolt variant) Millivolt, standing pilot Yes Aria explicitly sold in millivolt variant; fully compatible
Monessen Aria (IPI variant) IPI (electronic, battery-based) Yes – IPI on/off IPI variant uses simple on/off switch circuit; relay works
Monessen Symphony (millivolt variant) Millivolt, standing pilot Yes Millivolt variant available; fully compatible
Monessen Symphony (IPI variant) IPI (electronic) Yes – IPI on/off IPI control system; relay works
Monessen Solstice VFI33 (millivolt) Millivolt, standing pilot Yes Millivolt variant confirmed
Monessen Solstice VFI33 (IPI) IPI (electronic) Yes – IPI on/off IPI variant; relay works
Napoleon Ascent B36 / B46 (standing pilot) Millivolt, standing pilot Yes Pre-wired for wall switch; fully compatible
Napoleon Ascent B36NTRE / B46NTRE IPI (Napoleon Pilot on Demand, SIT-based) Yes – IPI on/off Napoleon's IPI uses dry-contact wall switch terminal; relay works
Napoleon Vector LV50 / LV62 IPI (Napoleon Pilot on Demand, SIT-based) Yes – IPI on/off IPI with CPI/IPI toggle; standard dry-contact switch; relay works
Napoleon Elevation E36 / E50 IPI (Napoleon Pilot on Demand, SIT-based) Yes – IPI on/off Same SIT-based IPI system; relay works
Napoleon Grandville VF36 / VF42 Millivolt, standing pilot Yes Vent-free millivolt; wall switch compatible
Napoleon Riverside 36 / 42 (outdoor) Millivolt, standing pilot Yes Outdoor millivolt models; fully compatible
Napoleon Inspiration GDIZC Millivolt, standing pilot Yes Millivolt confirmed; simple relay fully compatible
Napoleon Oakville X3 / X4 Millivolt, standing pilot Yes Traditional millivolt series
Napoleon Hearth BHD4 IPI (Napoleon Pilot on Demand) Yes – IPI on/off SIT-based IPI; relay works
Regency Ultimate U1500E / U2500E IPI/CPI (SIT ProFlame) Yes – IPI on/off ProFlame X4 connector is dry contact; CPI/IPI switch allows continuous pilot mode
Regency Panorama P33 / P36 / P44 IPI/CPI (SIT ProFlame) Yes – IPI on/off Same ProFlame system; relay works
Regency Horizon HRI4E / HRI6E IPI/CPI (SIT ProFlame) Yes – IPI on/off Confirmed ProFlame with dry-contact wall switch
Regency Liberty LRI4E IPI/CPI (SIT ProFlame) Yes – IPI on/off Same ProFlame system
Regency City series IPI (SIT ProFlame 1 – On Demand) Yes – IPI on/off ProFlame 1; X4 dry contact; relay works
Regency Classic C34E / C44E IPI/CPI (SIT ProFlame) Yes – IPI on/off ProFlame-based; simple relay works
Regency Grandview G600EC / G800EH IPI/CPI (SIT ProFlame 2) Yes – IPI on/off Confirmed ProFlame 2 with CPI/IPI switch; relay works
Superior DRT2000 (millivolt variant) Millivolt, standing pilot Yes MV version confirmed; standard dry-contact thermopile circuit
Superior DRT2000 (IPI variant) IPI/CPI (electronic) Yes – IPI on/off IPI/CPI switch standard; battery backup; relay works
Superior DRT3000 (millivolt variant) Millivolt, standing pilot Yes Millivolt available; wall switch compatible
Superior DRT3000 (IPI variant) IPI/CPI (electronic) Yes – IPI on/off IPI/CPI switch; relay works
Superior DRT3500 series IPI/CPI (electronic) Yes – IPI on/off Electronic ignition; relay works
Superior VRE / VRT4000 (millivolt) Millivolt, standing pilot Yes Vent-free millivolt variant confirmed
Superior VRE / VRT4000 (IPI variant) IPI (electronic) Yes – IPI on/off IPI electronic variant; relay works
Superior DRC series Millivolt or IPI Yes Both ignition options available; relay works with either
Valor L1 Linear 1500 / 1600 GV60 Electronic (Maxitrol, 6 V) Not compatible GV60 wall switch carries 6 V DC — not a passive dry contact. Foom's relay is not designed for this circuit.
Valor L2 Linear 1700 / 1800 GV60 Electronic (Maxitrol, 6 V) Not compatible Same GV60 system; incompatible
Valor Portrait 530 / 535 GV60 Electronic (Maxitrol, 6 V) Not compatible GV60 system; 6 V on switch terminals; incompatible
Valor Legend G3 738 / 739 GV60 Electronic (Maxitrol, 6 V) Not compatible GV60 system; incompatible
Valor Pre-GV60 models (older) Millivolt, standing pilot Yes Older Valor models before GV60 era used standard millivolt; verify by checking if model has a GV60 designation
Vermont Castings Radiance (millivolt variant) Millivolt, standing pilot Yes Sold explicitly in millivolt version; standard dry-contact wall switch; fully compatible
Vermont Castings Radiance (IntelliFire Touch variant) IPI (IntelliFire Touch – wireless RF) Not compatible IntelliFire Touch = wireless RF only; no wired 2-wire switch terminal available
Vermont Castings Intrepid (gas, millivolt variant) Millivolt, standing pilot Yes Millivolt gas Intrepid confirmed available; compatible
Vermont Castings Intrepid (IntelliFire Touch variant) IPI (IntelliFire Touch – wireless RF) Not compatible Same IntelliFire Touch issue; no wired switch option
No models found matching your filters. Contact us to ask about your specific model.
Quick reference

Decoding your model number

Many brands use suffixes or naming conventions to indicate the ignition system. Use this table to identify yours before looking it up above.

Suffix / Marking Meaning Compatible?
-MV, -1 (Napoleon) Millivolt, standing pilot Yes
No special suffix (many older models) Typically millivolt — verify with multimeter Verify first
-IPI, IPI, -IPC Intermittent Pilot Ignition (Dexen or similar) Yes – IPI on/off
GreenSmart 2, GSB, GS2 SIT ProFlame 2 (IPI) — Travis Industries / FPX Yes – IPI on/off
ProFlame 1, PF1 SIT ProFlame 1 (IPI) — Regency, Mendota, Kozy Heat Yes – IPI on/off
ProFlame 2, PF2, DT3, DT4 SIT ProFlame 2 (IPI) — Regency, Mendota, Kozy Heat Yes – IPI on/off
-NTRE (Napoleon) Napoleon Pilot on Demand (SIT-based IPI) Yes – IPI on/off
IntelliFire Touch, IFT Wireless RF system — Hearth & Home Technologies (Majestic, Vermont Castings, some Heatilator) Not compatible
GV60, Maxitrol Valor's 6 V electronic ignition system Not compatible
IntelliFire Plus, IPI+ Advanced Dexen IPI — may or may not have accessible terminals Check first
⚠️

When in doubt, measure first

With the pilot lit and the wall switch open, use a multimeter to measure the voltage across the two switch terminals. If it reads under 3 V DC, Foom is compatible. If it reads 24 V AC or higher, do not install Foom. If it reads around 6 V DC, you likely have a Valor GV60 system — not compatible.

Don't see your fireplace?

If you've tested Foom with a model not listed here — compatible or not — let us know. Your experience helps other buyers make an informed decision, and we'll add it to the list.

Submit your fireplace model