Compatibility Guide
Most gas fireplaces with a wall switch are compatible with Foom. Find your brand and model below, or use the three-step check to figure it out yourself.
Does your fireplace work with Foom? — 3 quick questions
-
1Does it have a wall switch? Look for a standard rocker or toggle switch that turns the fireplace on and off. If yes, continue to step 2. If it only has a key switch or physical valve knob, Foom is not compatible.
-
2Are the switch wires low-voltage? Behind the switch plate, the wires should carry no mains power. Measure across the two switch terminals (with the pilot lit but switch open) — a millivolt system will read 250–750 mV DC; an IPI system will read 0–3 V DC. Either is compatible. If you read 24 V AC or higher, Foom is not compatible.
-
3Is the wall switch wired, not wireless? Some current-generation fireplaces (primarily Majestic Meridian, Echelon, Ruby, Jade; and Valor L1/L2/Portrait/Legend) use a wireless RF wall switch with no wired terminals. These are not compatible without hardware modification.
What kind of fireplace do you have?
Gas fireplaces use one of a few ignition and control systems. Compatibility with Foom is determined almost entirely by the system type — not the brand.
✓ Millivolt / Standing Pilot
The most common type. A thermopile heated by the standing pilot generates 250–750 mV, which powers the gas valve directly. The wall switch is a simple dry-contact that completes the circuit. Fully compatible — Foom's relay acts as an electronic version of the wall switch.
✓ IPI with dry-contact switch
Intermittent Pilot Ignition systems using a Dexen IntelliFire board, SIT ProFlame 1 or 2, Napoleon Pilot on Demand, or Empire electronic IPI all expose a simple two-wire dry-contact wall switch terminal on the control board. Foom works for on/off control.
✗ IntelliFire Touch (wireless RF)
Used by current-generation Majestic (Meridian, Echelon, Ruby, Jade) and some Vermont Castings models. The wall switch communicates wirelessly — there are no wired low-voltage switch terminals. Incompatible with Foom without hardware modification.
✗ Valor GV60 (Maxitrol 6 V)
Valor's GV60 electronic ignition system puts 6 V DC on the wall switch circuit (rather than a passive dry contact). The wall switch kit (1265WSK) carries powered signal. Incompatible with Foom's relay.
⚠ Check first: IPI variant models
Many brands sell the same model in both millivolt and IPI configurations. Some older lines were millivolt; current versions may have switched to IntelliFire Touch. Always check your model number suffix and verify against this list.
Find your fireplace
Search by brand or model name, or filter by compatibility status. "IPI – on/off" means Foom controls the fireplace on and off; your existing wall switch continues to work normally through Foom.
| Brand | Model / Series | System type | Compatible | Notes |
|---|---|---|---|---|
| Empire | Tahoe DVP / DVC (MV models) | Millivolt, standing pilot | Yes | Suffix MV or DVP confirms millivolt; standard thermopile circuit |
| Empire | Tahoe DVP / DVC (IPC models) | IPI (electronic) | Yes – IPI on/off | IPC (Intermittent Pilot Control) version; dry-contact wall switch terminal on board |
| Empire | Loft DVL36 / DVL46 | IPI (electronic, battery backup) | Yes – IPI on/off | Includes manual wall switch; IPI with dry-contact two-wire terminal |
| Empire | Boulevard DVLL (direct vent) | IPI (electronic) | Yes – IPI on/off | IPI system with standard wall switch terminal |
| Empire | Carol Rose OP36 / OP42 (MV) | Millivolt, standing pilot | Yes | Outdoor millivolt models; standard thermopile circuit |
| Empire | Madison | Millivolt, standing pilot | Yes | Traditional millivolt series |
| Fireplace Xtrordinair | 4415 HO Deluxe (MV variant) | Millivolt, standing pilot | Yes | ProBuilder and some 4415 available in millivolt version |
| Fireplace Xtrordinair | 4415 HO Deluxe (GreenSmart 2) | IPI (SIT ProFlame 2) | Yes – IPI on/off | GreenSmart 2 uses SIT ProFlame 2; X4 connector is dry contact |
| Fireplace Xtrordinair | 564 TRV (MV variant) | Millivolt, standing pilot | Yes | MV suffix confirms millivolt |
| Fireplace Xtrordinair | 564 SS / 564 TRV (GreenSmart 2) | IPI (SIT ProFlame 2) | Yes – IPI on/off | GreenSmart 2; dry-contact relay works |
| Fireplace Xtrordinair | 616 (MV variant) | Millivolt, standing pilot | Yes | MV models available |
| Fireplace Xtrordinair | 616 (GreenSmart 2 variant) | IPI (SIT ProFlame 2) | Yes – IPI on/off | GreenSmart 2 IPI; relay works |
| Fireplace Xtrordinair | 4015 (legacy) | Millivolt, standing pilot | Yes | Legacy models were millivolt; confirm if GreenSmart upgrade was applied |
| Heat & Glo | 6000C / 6000G (non-IPI) | Millivolt, standing pilot | Yes | Classic millivolt models; wall switch closes thermopile circuit directly |
| Heat & Glo | 6000CBV-IPI / 6000GBV-IPI | IPI (Dexen IntelliFire) | Yes – IPI on/off | Switch terminals carry <3 V from Dexen board; dry-contact relay works |
| Heat & Glo | 6000XLS / 6000XLT | Millivolt, standing pilot | Yes | Standing pilot millivolt; full wall switch compatibility |
| Heat & Glo | SLIMLINE (non-IPI suffix) | Millivolt, standing pilot | Yes | Model number without "-IPI" indicates millivolt variant |
| Heat & Glo | SLIMLINE SL-550TR-IPI / SL-750TR-IPI / SL-950TV-IPI | IPI (Dexen IntelliFire) | Yes – IPI on/off | Relay replaces simple on/off function at Dexen board switch terminals |
| Heat & Glo | ST series (non-IPI) | Millivolt, standing pilot | Yes | Non-IPI ST variants use millivolt |
| Heat & Glo | ST-36TR-IPI / PIER-36TR-IPI | IPI (Dexen IntelliFire) | Yes – IPI on/off | Simple relay works at Dexen board switch terminals |
| Heat & Glo | COSMO series | IPI (IntelliFire / IntelliFire Plus – varies by year) | Check first | Newer COSMO models use IntelliFire Plus; may require proprietary WSK-21 switch. Verify model year and check if board has accessible dry-contact terminals. |
| Heat & Glo | MEZZO series | IPI (IntelliFire Plus) | Check first | IntelliFire Plus models may not expose simple 2-wire terminals; consult installation manual for your specific model year |
| Heatilator | ICON series (pre-2020, non-IPI) | Millivolt, standing pilot | Yes | Older ICON DV models with standing pilot; standard thermopile circuit |
| Heatilator | ICON I100 (current) | IPI (IntelliFire) | Yes – IPI on/off | Relay works at Dexen board switch terminals |
| Heatilator | EL / Eclipse (older) | Millivolt, standing pilot | Yes | Older Eclipse models used millivolt standing pilot |
| Heatilator | SC / ST series (non-IPI designation) | Millivolt, standing pilot | Yes | Models without IPI designation in the model number use millivolt |
| Heatilator | CRAVE series | IPI (IntelliFire / IntelliFire Touch – varies by year) | Check first | Newer CRAVE uses IntelliFire Touch (wireless only — incompatible). Older CRAVE may have standard wired option. Check model year carefully. |
| Kozy Heat | Chaska 25 | IPI (electronic) | Yes – IPI on/off | Standard IPI with dry-contact wall switch terminal |
| Kozy Heat | Chaska 29 | IPI (electronic) or Millivolt (optional) | Yes | Both IPI and optional millivolt available; both compatible |
| Kozy Heat | Chaska 34 | IPI (electronic) | Yes – IPI on/off | Standard IPI; dry-contact relay works |
| Kozy Heat | Chaska 335s | Millivolt, standing pilot | Yes | Confirmed millivolt standard on this model |
| Kozy Heat | Callaway 50 / Callaway 72 | IPI (SIT ProFlame) | Yes – IPI on/off | SIT ProFlame-based; X4 connector is dry contact; relay works |
| Kozy Heat | Slayton 36 / Slayton 42 | IPI (SIT ProFlame) | Yes – IPI on/off | Same SIT ProFlame system as Callaway; relay works |
| Majestic | Meridian 36 / 42 | IPI (IntelliFire Touch – wireless RF) | Not compatible | IntelliFire Touch uses wireless RF; no wired 2-wire low-voltage switch terminals available |
| Majestic | Echelon II 36 / 42 / 60 | IPI (IntelliFire Touch – wireless RF) | Not compatible | Same IntelliFire Touch system; no wired switch option available |
| Majestic | Ruby series | IPI (IntelliFire Touch – wireless RF) | Not compatible | IntelliFire Touch throughout current Ruby line |
| Majestic | Jade series | IPI (IntelliFire Touch – wireless RF) | Not compatible | IntelliFire Touch throughout current Jade line |
| Majestic | Quartz series (older) | IPI (IntelliFire / original Dexen) | Yes – IPI on/off | Older Quartz used standard IntelliFire (not Touch); relay works at Dexen board terminals |
| Majestic | Marquis series | Varies by generation | Check first | Some older Marquis were millivolt (compatible); newer generations may be IntelliFire or IntelliFire Touch. Verify model year. |
| Mendota | DXV-35 / DXV-42 / DXV-45 (manual control) | Millivolt, standing pilot | Yes | Manual control DXV models use millivolt valve; standard dry-contact wall switch |
| Mendota | DXV-35 / DXV-42 (DT3 / DT4 – ProFlame 2) | IPI (SIT ProFlame 2) | Yes – IPI on/off | ProFlame 2 X4 connector is dry contact; relay works; wireless transmitter is optional |
| Mendota | ML39 / ML39-PF2 | IPI (SIT ProFlame 2) | Yes – IPI on/off | Confirmed ProFlame 2 system; dry-contact wall switch |
| Mendota | FV series / FullView | IPI (SIT ProFlame 2) | Yes – IPI on/off | ProFlame 2-based; relay works |
| Monessen | Aria (millivolt variant) | Millivolt, standing pilot | Yes | Aria explicitly sold in millivolt variant; fully compatible |
| Monessen | Aria (IPI variant) | IPI (electronic, battery-based) | Yes – IPI on/off | IPI variant uses simple on/off switch circuit; relay works |
| Monessen | Symphony (millivolt variant) | Millivolt, standing pilot | Yes | Millivolt variant available; fully compatible |
| Monessen | Symphony (IPI variant) | IPI (electronic) | Yes – IPI on/off | IPI control system; relay works |
| Monessen | Solstice VFI33 (millivolt) | Millivolt, standing pilot | Yes | Millivolt variant confirmed |
| Monessen | Solstice VFI33 (IPI) | IPI (electronic) | Yes – IPI on/off | IPI variant; relay works |
| Napoleon | Ascent B36 / B46 (standing pilot) | Millivolt, standing pilot | Yes | Pre-wired for wall switch; fully compatible |
| Napoleon | Ascent B36NTRE / B46NTRE | IPI (Napoleon Pilot on Demand, SIT-based) | Yes – IPI on/off | Napoleon's IPI uses dry-contact wall switch terminal; relay works |
| Napoleon | Vector LV50 / LV62 | IPI (Napoleon Pilot on Demand, SIT-based) | Yes – IPI on/off | IPI with CPI/IPI toggle; standard dry-contact switch; relay works |
| Napoleon | Elevation E36 / E50 | IPI (Napoleon Pilot on Demand, SIT-based) | Yes – IPI on/off | Same SIT-based IPI system; relay works |
| Napoleon | Grandville VF36 / VF42 | Millivolt, standing pilot | Yes | Vent-free millivolt; wall switch compatible |
| Napoleon | Riverside 36 / 42 (outdoor) | Millivolt, standing pilot | Yes | Outdoor millivolt models; fully compatible |
| Napoleon | Inspiration GDIZC | Millivolt, standing pilot | Yes | Millivolt confirmed; simple relay fully compatible |
| Napoleon | Oakville X3 / X4 | Millivolt, standing pilot | Yes | Traditional millivolt series |
| Napoleon | Hearth BHD4 | IPI (Napoleon Pilot on Demand) | Yes – IPI on/off | SIT-based IPI; relay works |
| Regency | Ultimate U1500E / U2500E | IPI/CPI (SIT ProFlame) | Yes – IPI on/off | ProFlame X4 connector is dry contact; CPI/IPI switch allows continuous pilot mode |
| Regency | Panorama P33 / P36 / P44 | IPI/CPI (SIT ProFlame) | Yes – IPI on/off | Same ProFlame system; relay works |
| Regency | Horizon HRI4E / HRI6E | IPI/CPI (SIT ProFlame) | Yes – IPI on/off | Confirmed ProFlame with dry-contact wall switch |
| Regency | Liberty LRI4E | IPI/CPI (SIT ProFlame) | Yes – IPI on/off | Same ProFlame system |
| Regency | City series | IPI (SIT ProFlame 1 – On Demand) | Yes – IPI on/off | ProFlame 1; X4 dry contact; relay works |
| Regency | Classic C34E / C44E | IPI/CPI (SIT ProFlame) | Yes – IPI on/off | ProFlame-based; simple relay works |
| Regency | Grandview G600EC / G800EH | IPI/CPI (SIT ProFlame 2) | Yes – IPI on/off | Confirmed ProFlame 2 with CPI/IPI switch; relay works |
| Superior | DRT2000 (millivolt variant) | Millivolt, standing pilot | Yes | MV version confirmed; standard dry-contact thermopile circuit |
| Superior | DRT2000 (IPI variant) | IPI/CPI (electronic) | Yes – IPI on/off | IPI/CPI switch standard; battery backup; relay works |
| Superior | DRT3000 (millivolt variant) | Millivolt, standing pilot | Yes | Millivolt available; wall switch compatible |
| Superior | DRT3000 (IPI variant) | IPI/CPI (electronic) | Yes – IPI on/off | IPI/CPI switch; relay works |
| Superior | DRT3500 series | IPI/CPI (electronic) | Yes – IPI on/off | Electronic ignition; relay works |
| Superior | VRE / VRT4000 (millivolt) | Millivolt, standing pilot | Yes | Vent-free millivolt variant confirmed |
| Superior | VRE / VRT4000 (IPI variant) | IPI (electronic) | Yes – IPI on/off | IPI electronic variant; relay works |
| Superior | DRC series | Millivolt or IPI | Yes | Both ignition options available; relay works with either |
| Valor | L1 Linear 1500 / 1600 | GV60 Electronic (Maxitrol, 6 V) | Not compatible | GV60 wall switch carries 6 V DC — not a passive dry contact. Foom's relay is not designed for this circuit. |
| Valor | L2 Linear 1700 / 1800 | GV60 Electronic (Maxitrol, 6 V) | Not compatible | Same GV60 system; incompatible |
| Valor | Portrait 530 / 535 | GV60 Electronic (Maxitrol, 6 V) | Not compatible | GV60 system; 6 V on switch terminals; incompatible |
| Valor | Legend G3 738 / 739 | GV60 Electronic (Maxitrol, 6 V) | Not compatible | GV60 system; incompatible |
| Valor | Pre-GV60 models (older) | Millivolt, standing pilot | Yes | Older Valor models before GV60 era used standard millivolt; verify by checking if model has a GV60 designation |
| Vermont Castings | Radiance (millivolt variant) | Millivolt, standing pilot | Yes | Sold explicitly in millivolt version; standard dry-contact wall switch; fully compatible |
| Vermont Castings | Radiance (IntelliFire Touch variant) | IPI (IntelliFire Touch – wireless RF) | Not compatible | IntelliFire Touch = wireless RF only; no wired 2-wire switch terminal available |
| Vermont Castings | Intrepid (gas, millivolt variant) | Millivolt, standing pilot | Yes | Millivolt gas Intrepid confirmed available; compatible |
| Vermont Castings | Intrepid (IntelliFire Touch variant) | IPI (IntelliFire Touch – wireless RF) | Not compatible | Same IntelliFire Touch issue; no wired switch option |
| No models found matching your filters. Contact us to ask about your specific model. | ||||
Decoding your model number
Many brands use suffixes or naming conventions to indicate the ignition system. Use this table to identify yours before looking it up above.
| Suffix / Marking | Meaning | Compatible? |
|---|---|---|
| -MV, -1 (Napoleon) | Millivolt, standing pilot | Yes |
| No special suffix (many older models) | Typically millivolt — verify with multimeter | Verify first |
| -IPI, IPI, -IPC | Intermittent Pilot Ignition (Dexen or similar) | Yes – IPI on/off |
| GreenSmart 2, GSB, GS2 | SIT ProFlame 2 (IPI) — Travis Industries / FPX | Yes – IPI on/off |
| ProFlame 1, PF1 | SIT ProFlame 1 (IPI) — Regency, Mendota, Kozy Heat | Yes – IPI on/off |
| ProFlame 2, PF2, DT3, DT4 | SIT ProFlame 2 (IPI) — Regency, Mendota, Kozy Heat | Yes – IPI on/off |
| -NTRE (Napoleon) | Napoleon Pilot on Demand (SIT-based IPI) | Yes – IPI on/off |
| IntelliFire Touch, IFT | Wireless RF system — Hearth & Home Technologies (Majestic, Vermont Castings, some Heatilator) | Not compatible |
| GV60, Maxitrol | Valor's 6 V electronic ignition system | Not compatible |
| IntelliFire Plus, IPI+ | Advanced Dexen IPI — may or may not have accessible terminals | Check first |
When in doubt, measure first
With the pilot lit and the wall switch open, use a multimeter to measure the voltage across the two switch terminals. If it reads under 3 V DC, Foom is compatible. If it reads 24 V AC or higher, do not install Foom. If it reads around 6 V DC, you likely have a Valor GV60 system — not compatible.
Don't see your fireplace?
If you've tested Foom with a model not listed here — compatible or not — let us know. Your experience helps other buyers make an informed decision, and we'll add it to the list.
Submit your fireplace model